Mixing refrigerants can cause

Respuesta :

Аноним Аноним
  • 09-12-2019

Answer:

When an alternative refrigerant is mixed with R-22, there is no pressure-temperature chart to refer to and therefore no way to optimize the system charge. Improper superheat or subcooling can lead to compressor floodback, overheating, and dramatically reduce system efficiency and compressor lifetime